Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative.
This standard is developed in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB 12021.3-2010 The minimum allowable value of the energy efficiency and energy efficiency grades for room air conditioners and GB 21455-2013 Minimum allowable values of the energy efficiency and energy efficiency grades for variable speed room air conditioners. In addition to editorial changes, the following main technical changes have been made with respect to GB 12021.3-2010 and GB 21455-2013:
——the scope of this standard is revised (see Clause 1);
——the energy efficiency grade indexes of products are revised (see Clause 4);
——the minimum allowable values of the energy efficiency are revised (see 5.1).
This standard was proposed by the Standardization Administration of the People’s Republic of China and the Department of Resource Conservation and Environmental Protection of the National Development and Reform Commission of the People's Republic of China.
This standard is under the jurisdiction of the Standardization Administration of the People’s Republic of China.
The previous editions of this standard are as follows:
——GB 12021.3-1989, GB 12021.3-2000, GB 12021.3-2004 and GB 12021.3-2010;
——GB 21455-2008 and GB 21455-2013.
Minimum allowable values of the energy efficiency and energy efficiency grades for room air conditioners
1 Scope
This standard specifies the energy efficiency grades, minimum allowable values of the energy efficiency and test methods for room air conditioners.
This standard is applicable to the room air conditioners with air-cooled condensers, fully enclosed electric compressors, rated cooling capacity not greater than 14,000 W and climate type T1, as well as the low ambient temperature air source heat pump air heaters with nominal heating capacity not greater than 14,000W.
This standard is not applicable to portable air conditioners, VRV air conditioning units and air duct air conditioners.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 7725-2004 Room air conditioners
GB/T 35758-2017 Household electrical appliances - Measurement of standby power
JB/T 13573-2018 Low ambient temperature air source heat pump air heaters
3 Terms and definitions
For the purposes of this document, the terms and definitions given in GB/T 7725-2004 and JB/T 13573-2018 as well as the following apply.
3.1
minimum allowable values of energy efficiency for room air conditioners
minimum allowable value of energy efficiency during cooling and heating operation under specified working conditions
3.2
minimum allowable values of energy efficiency for low ambient temperature air source heat pump air heaters
minimum allowable value of the heating seasonal performance factor during heating operation under specified working conditions
3.3
energy consumption in standby mode
energy consumption of the product when powered on but in a non-working state; standby mode is the lowest energy consumption mode of the appliance, in which, the appliance timely monitors the control signals from the remote control device, internal sensor or similar devices that enable it to enter the working state
Note: in this mode, the input power of protection devices with similar functions such as crankcase heater is not included.
4 Energy efficiency grades
4.1 Energy efficiency grades of room air conditioners
4.1.1 The energy efficiency of room air conditioners is classified into five grades, of which, Grade 1 is the highest.
4.1.2 The energy efficiency of heat pump room air conditioners is graded according to the measured annual performance factor (APF) of the product, and APF for each energy efficiency grade shall not be less than that specified in Table 1.
Table 1 Indexes of energy efficiency grades for heat pump room air conditioners
Rated cooling capacity (CC)
W Annual performance factor (APF)
Energy efficiency grade
Grade 1 Grade 2 Grade 3 Grade 4 Grade 5
CC≤4 500 5.00 4.50 4.00 3.50 3.30
4 500
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Energy efficiency grades
5 Technical requirements
6 Test methods
7 Implementation of this standard
Annex A (Normative) Test and calculation methods of seasonal energy efficiency ratio (SEER) and heating seasonal performance factor (HSPF) for room air conditioners
Annex B (Normative) Occurrence time of each temperature in outdoor environment during operation of room air conditioner in cooling and heating seasons
Annex C (Normative) Unsteady-state heating test method
房間空氣調節器能效限定值及能效等級
1 范圍
本標準規定了房間空氣調節器的能效等級、能效限定值和試驗方法。
本標準適用于采用空氣冷卻冷凝器、全封閉電動壓縮機,額定制冷量不大于14 000 W、氣候類型為T1的房間空氣調節器和名義制熱量不大于14 000 W的低環境溫度空氣源熱泵熱風機。
本標準不適用于移動式空調器、多聯式空調機組、風管送風式空調器。
2規范性引用文件
下列文件對于本文件的應用是必不可少的。凡是注日期的引用文件,僅注日期的版本適用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改單)適用于本文件。
GB/T 7725—2004 房間空氣調節器
GB/T 35758—2017家用電器待機功率測量方法
JB/T l3573—2018低環境溫度空氣源熱泵熱風機
3術語和定義
GB/T 7725—2004、JB/T l3573—2018界定的以及下列術語和定義適用于本文件。
3.1
房間空氣調節器能效限定值 minimum allowable values of energy efficiency for room air-condi-tioners
在規定工況條件下制冷和制熱運行時,能源消耗效率的最小允許值。
3.2
低環境溫度空氣源熱泵熱風機能效限定值 minimum allowable values of energy efficiency for low ambient temperature air source heat pump air heaters
在規定工況條件下制熱運行時,制熱季節性能系數的最小允許值。
3.3
待機功率 energy consumption in standby mode
產品接通電源但處于非工作狀態的模式下的功率。該模式是器具的最低能耗模式,在待機狀態下器具隨時監測來自遙控裝置、內部傳感器或類似裝置的可使其進入工作狀態的控制信號。
注:該模式下不包含曲軸箱加熱器等類似功能保護裝置的輸入功率。
4能效等級
4.1房間空調器能效等級
4.1.1房間空氣調節器能效等級分為5級,其中1級能效等級最高。
4.1.2熱泵型房間空氣調節器根據產品的實測全年能源消耗效率(APF)對產品能效分級,各能效等級實測全年能源消耗效率(APF)應不小于表1規定。
表1 熱泵型房間空氣調節器能效等級指標值
額定制冷量(CC)
W 全年能源消耗效率(APF)
能效等級
1級 2級 3級 4級 5級
CC≤4 500 5.00 4.50 4.00 3.50 3.30
4 500
GB 21455-2019 引用如下標準: |
GB 21455-2019被如下標準引用:
|